
Shipping Estimate
USA
- USA
- CAN
- USA
- CAN
Ships within 48 hours · Estimated delivery Jul 7 - Jul 12
For Your Every Summer RSVP, with Code: SUMMER15
Description
LUB32Main Range TeSys Product name TeSys U Device short name LUB Product or component type Non reversing power base Device application Motor Poles description 3P Suitability for isolation Yes [Ith] conventional free air thermal current 32 A Utilisation category AC 44 AC 43 AC 41 [Uc] control circuit voltage 24 V AC 50 60 Hz 24 V DC 48 V AC 50 60 Hz 48 72 V DC 110 220 V DC 110 240 V AC 50 60 Hz Complementary Auxiliary contact composition 1 NO + 1 NC
Main
| Range | TeSys |
| Product name | TeSys U |
| Device short name | LUB |
| Product or component type | Non reversing power base |
| Device application | Motor |
| Poles description | 3P |
| Suitability for isolation | Yes |
| [Ith] conventional free air thermal current | 32 A |
| Utilisation category | AC-44 AC-43 AC-41 |
| [Uc] control circuit voltage | 24 V AC 50/60 Hz 24 V DC 48 V AC 50/60 Hz 48...72 V DC 110...220 V DC 110...240 V AC 50/60 Hz |
Complementary
| Auxiliary contact composition | 1 NO + 1 NC |
| Auxiliary contacts type | Type linked contacts (1 NO + 1 NC) conforming to IEC 60947-4-1 Type mirror contact (1 NC) state of the power conforming to draft IEC 60947-1 |
| [Ue] rated operational voltage | 230 V 440 V 500 V 690 V |
| Network frequency | 40...60 Hz |
| [Ie] rated operational current | 21 A at 690 V 23 A at 500 V 32 A at <= 440 V |
| [Ics] rated service breaking capacity | 10 kA at 500 V 4 kA at 690 V 50 kA at 230 V 50 kA at 440 V |
| Typical current consumption | 200 mA at 24 V DC I maximum while closing with LUCM 220 mA at 24 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD 220 mA at 24 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD 25 mA at 110...220 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD 25 mA at 110...240 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD 280 mA at 110...220 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD 280 mA at 110...240 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD 280 mA at 48...72 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD 280 mA at 48...72 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD 45 mA at 48...72 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD 45 mA at 48...72 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD 75 mA at 24 V DC I rms sealed with LUCM 80 mA at 24 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD 90 mA at 24 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD |
| Safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
| Operating time | 35 ms opening with LUCA, LUCB, LUCC, LUCD, LUCM for control circuit 50 ms at >= 72 V closing with LUCA, LUCB, LUCC, LUCD for control circuit 60 ms at 48 V closing with LUCA, LUCB, LUCC, LUCD for control circuit 70 ms at 24 V closing with LUCA, LUCB, LUCC, LUCD for control circuit 65 ms closing with LUCM for control circuit |
| Mechanical durability | 15000000 cycles |
| Maximum operating rate | 60 cyc/mn |
| [Ui] rated insulation voltage | 600 V conforming to UL 508 690 V conforming to IEC 60947-1 (pollution degree 3) 600 V conforming to CSA C22.2 No 14 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947-6-2 |
| Safe separation of circuit | 400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1 appendix N 400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1 appendix N |
| Connections - terminals | Control circuit: screw clamp terminals 1 cable(s) 0.34…1.5 mm² flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 0.75…1.5 mm² flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 0.75…1.5 mm² rigid without cable end Control circuit: screw clamp terminals 2 cable(s) 0.34…1.5 mm² flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 0.75…1.5 mm² flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 0.75…1.5 mm² rigid without cable end Power circuit: screw clamp terminals 1 cable(s) 1…10 mm² rigid without cable end Power circuit: screw clamp terminals 1 cable(s) 1…6 mm² flexible with cable end Power circuit: screw clamp terminals 1 cable(s) 2.5…10 mm² flexible without cable end Power circuit: screw clamp terminals 2 cable(s) 1…6 mm² flexible with cable end Power circuit: screw clamp terminals 2 cable(s) 1…6 mm² rigid without cable end Power circuit: screw clamp terminals 2 cable(s) 1.5…6 mm² flexible without cable end |
| Tightening torque | Control circuit: 0.8…1.2 N.m flat screwdriver 5 mm Control circuit: 0.8…1.2 N.m Philips no 1 screwdriver 5 mm Power circuit: 1.9…2.5 N.m flat screwdriver 6 mm Power circuit: 1.9…2.5 N.m Philips No 2 screwdriver 6 mm |
| Width | 45 mm |
| Height | 145 mm |
| Depth | 126 mm |
| Net weight | 0.9 kg |
Environment
| Heat dissipation | 3 W for control circuit with LUCA, LUCB, LUCC, LUCD 1.8 W for control circuit with LUCM |
| Immunity to microbreaks | 3 ms |
| Immunity to voltage dips | 70 % / 500 ms conforming to IEC 61000-4-11 |
| Product certifications | LROS (Lloyds register of shipping) CCC ABS CSA ASEFA UL GL GOST ATEX BV DNV |
| Standards | UL 508 type E, with phase barrier EN 60947-6-2 IEC 60947-6-2 CSA C22.2 No 14 type E |
| IP degree of protection | IP20 conforming to IEC 60947-1 (front panel and wired terminals) IP20 conforming to IEC 60947-1 (other faces) IP40 conforming to IEC 60947-1 (front panel outside connection zone) |
| Protective treatment | TH conforming to IEC 60068 |
| Ambient air temperature for operation | -25…60 °C with LUCM -25…70 °C with LUCA, LUCB, LUCC, LUCD |
| Ambient air temperature for storage | -40…85 °C |
| Fire resistance | 960 °C parts supporting live components conforming to IEC 60695-2-12 650 °C conforming to IEC 60695-2-12 |
| Operating altitude | 2000 m |
| Shock resistance | 10 gn power poles open conforming to IEC 60068-2-27 15 gn power poles closed conforming to IEC 60068-2-27 |
| Vibration resistance | 2 gn (f= 5…300 Hz) power poles open conforming to IEC 60068-2-27 4 gn (f= 5…300 Hz) power poles closed conforming to IEC 60068-2-27 |
| Resistance to electrostatic discharge | 8 kV level 3 in open air conforming to IEC 61000-4-2 8 kV level 4 on contact conforming to IEC 61000-4-2 |
| Resistance to radiated fields | 10 V/m 3 conforming to IEC 61000-4-3 |
| Resistance to fast transients | 2 kV class 3 serial link conforming to IEC 61000-4-4 4 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4 |
| Non-dissipating shock wave | 1 kV serial mode 24...240 V AC conforming to IEC 60947-6-2 1 kV serial mode 48...220 V DC conforming to IEC 60947-6-2 2 kV common mode 24...240 V AC conforming to IEC 60947-6-2 2 kV common mode 48...220 V DC conforming to IEC 60947-6-2 |
| Immunity to radioelectric fields | 10 V conforming to IEC 61000-4-6 |
Offer Sustainability
| Sustainable offer status | Green Premium product |
| REACh Regulation | REACh Declaration |
| EU RoHS Directive | Compliant EU RoHS Declaration |
| Mercury free | Yes |
| RoHS exemption information | Yes |
| China RoHS Regulation | China RoHS declaration |
| Environmental Disclosure | Product Environmental Profile |
| Circularity Profile | End of Life Information |
| WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
Contractual warranty
| Warranty | 18 months |
Shipping Notes
- Free Standard Shipping on $100+ Orders to the USA.
- Except Preorder products are shipped in 48 hours.
- Delivery to the USA:
- Standard Shipping : 3-10 business days
- If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
- We offer a 30-day return/exchange service after receiving.
- Final sale items are not eligible for returns or exchanges.
- To process your return/exchange, please contact us at [email protected]
- Please click here for more details>>> Return & Exchange Policy
4.2 ★★★★★
Based on 750 reviews
Sort
Product Reviews
★★★★★ 5
Replacement Roller brush for my robovac
when you have long-haired dogs... these rollers WILL get tangled up with yards of hair...and although you can (and we do) take them out...and clean them off, after a while, the design of the roller is changed because of these tangles... This replacement roller is great, easy to install, and cost effective. would recommend if for no other reason, than keeping my house cleaner
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on April 22, 2026
★★★★★ 5
Fits Perfect
This fits my cordless P10 Pro perfectly. It has some foam and hard grooves for picking up debris. The part feels very solid, not cheap or low quality at all. Be sure your Dreame is one of the models listed as this only fits those. It won't fit any of the other brands that share some of the Dreame parts (like Mova, for example). The rollers do eventually wear and reduce performance. This is a nice alternative to the name brand.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on December 19, 2025
★★★★★ 5
Perfect Fit & Performance
Style: with Pre-Filter
These are an excellent, cost-effective alternative to OEM parts. The brushes and filters fit securely, restore full suction power, and hold up well to daily use. A must-have for maintaining a Eufy RoboVac without the high brand-name price tag.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on March 24, 2026
★★★★★ 5
Fits well
Style: with Pre-Filter
Good product
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 22, 2026
★★★★★ 5
Works great!
Style: with Pre-Filter
I bought this set to put on my original euphy robot vacuum. It works perfect! All pieces fit perfectly and were so easy to change out. I’ve had the new parts installed for a few weeks and it works so much better now. I recommend them for sure if you need any new parts for yours!
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 20, 2026